Index |
Identifier |
Field Type |
Field Length |
Description |
Units |
0 |
"dsr_time" |
MJD |
1 |
Time of the first line in the MDS corresponding to this record. |
MJD |
1 |
"attach_flag" |
UChar |
1 |
Attachment Flag (Set to 1 if all the records in all the bands are blank for the period corresponding to this
record, set to zero otherwise) |
flag |
2 |
"range_flag" |
UShort |
5 |
Out of Range flag. For every band, when the number of out of range samples is above a given threshold then
it is set to TRUE, otherwise it is left to FALSE. The 15 flags for all the bands of a module are stored in
an unsigned integer. To have this information for every MERIS module, five unsigned integers are needed. |
flag |
3 |
"range_blind_flag" |
UShort |
5 |
Out of Range blind flag. Flags set to TRUE when the number of out of range blind spectral samples per module
is above a given threshold. Flag ordering same as described in field 3. |
flag |